OUZHI Cable
Solar PV Cables · Utility Scale · 2026

Solar PV Cables: 1500 V DC Rated, 25 Years Outdoors

OUZHI Cable (欧智电缆) — source factory for solar farms

H1Z2Z2-K and PV1-F cables to EN 50618 and TÜV 2 PfG 1169, with XLPO insulation rated for UV, ozone, salt and 120°C continuous service — plus 26/35 kV AC collector cables for the whole solar plant.

Why Ordinary Cable Fails on a Solar Farm

PV cable lives outdoors for 25 years: full UV, ozone, thermal cycling every day, and 1500 V DC that never crosses zero. Four details decide whether it lasts.

01
XLPO, Not PVC
Cross-linked polyolefin insulation — halogen-free, 120°C continuous, 250°C short-circuit. PVC embrittles within a few years outdoors.
02
1500 V DC Rated
Full 1.5 kV DC rating with DC-specific test regime — not an AC cable re-labelled for PV.
03
UV, Ozone, Salt
Weather-resistant sheath tested to EN 50618 and IEC 62930 for outdoor exposure in desert and coastal plants.
04
TÜV / EN 50618 Certified
Type-tested to EN 50618 (H1Z2Z2-K) and TÜV 2 PfG 1169 — the certificates EPCs, lenders and insurers ask for.

PV Plant Cable Map: DC to AC

Reference allocation for a utility-scale plant — final sizing by your PV electrical engineer.

PositionTypical CableRatingStandard
Module to stringH1Z2Z2-K solar cable1500 V DC / 1.5–6 mm²EN 50618
String to inverterH1Z2Z2-K or PV1-F1500 V DC / 6–16 mm²EN 50618 / TÜV 2 PfG 1169
Inverter to MV substationXLPE medium voltage26/35 kVIEC 60502-2

The Certification Trap in PV Cables

Many "solar cables" are PVC house cables with a green sheath. Before you approve a supplier, ask for the EN 50618 type test report and confirm the insulation compound is XLPO — the certificate number, not just the logo, on the drum.

FAQ — PV Cable Buyers

What is the difference between H1Z2Z2-K and PV1-F?
H1Z2Z2-K is the EN 50618 cross-linked 1500 V DC cable; PV1-F is the older TÜV 2 PfG 1169 designation. Both are available — H1Z2Z2-K is the current preference for new plants.
Can I use ordinary AC cable for DC strings?
No. DC arcs do not self-extinguish at zero crossing, and AC cable is not rated or tested for continuous 1500 V DC or UV exposure.
What cross-section do I need?
Typically 4–6 mm² on module-to-string and 6–16 mm² to the inverter, set by current, voltage drop and string length. Send us your string layout.
Do you supply AC collector cable too?
Yes — 26/35 kV XLPE collector feeders from inverter stations to the MV substation, so one supplier covers the whole plant.

Related Product Pages

Compare the cable construction for your application — each page covers the standards, ratings and procurement checks that matter at the quotation stage.

Let's Discuss Your 35 kV Cable Project

Tell us your project location, voltage and cable requirements. Our export engineers will reply within 24 hours with a tailored solution and factory-direct quotation.

Email: info@ouzcable.com
Phone: +998 99 851 6999
WhatsApp: +998 99 851 6999
Telegram: @H99G99
HQ: China · Export Worldwide
Website: www.ouzcable.com